Part Number Hot Search : 
RCA113B TS8MED N7002 SBR30 4416P RB160 1SMA5938 10700469
Product Description
Full Text Search
 

To Download MW128XA070301 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ault incorporated 7105 northland terrace | minneapolis, minnesota 55428 | usatel (1) 763-592-1900 fax (1) 763-592-1911 | e-mail info@aultinc.com | web www.aultinc.com ? copyright 2002 ault inc. mw128 switch-mode power supply ? 100-240 vac universal input ? desktop style or wallplug style ? single output to 32w ? regulated output with low ripple ? meets medical safety agency requirements ? complies with emi/rfi regulations ? ce compliant ? impact resistant polycarbonate enclosure ? private label marking available ? 1 year warranty ? modified and custom designs also available mw128 medical 13-32 watt series mw128xa0303_01 3.3v 4.00 13.2 mw128xa0503_01 5v 4.00 20.0 mw128xa0703_01 7v 3.50 24.5 mw128xa0903_01 9v 3.00 27.0 mw128xa1203_01 12v 2.50 30.0 mw128xa1503_01 15v 2.00 30.0 mw128xa1803_01 18v 1.67 30.1 mw128xa2403_01 24v 1.33 32.0 mw128 x a 05 03 __ 01 product manufacturing design voltage connector input denotes family location revision dc configuration/ standard name (volume changes model type or custom dependent) (see pg. 2) requirements voltage max max ault part no. dc amps watts ault part no. key ault part no. key mw128
ault incorporated 7105 northland terrace | minneapolis, minnesota 55428 | usatel (1) 763-592-1900 fax (1) 763-592-1911 | e-mail info@aultinc.com | web www.aultinc.com ? copyright 2002 ault inc. inlet type: iec320-c14, c18, c8 plug type: na, euro, uk, saa specify the input configuration code in your order. connector input configuration mw128 medical 13-32 watt series iec320 w/ground c14 (f) iec320 w/o ground c18 (q) n. america/ japan (b) europe (m) united kingdom (g) shaver c8 (n) pinout code center contact: positive description switchcraft 760 plug or equivalent suggested mating switchcraft 712a jack or equivalent other connectors are available by special order input voltage 100-240 vac +/-10% line frequency 47 - 63 hz current tbd max at 90 vac input protection internal primary current fuse, inrush limiting output combined line and load 1% excluding cord voltage regulation ripple 1% v p-p max for output current of >0.175a transient response 0.5 msec. for 50% load change typical holdup time 18 msec min. @ 120vac, protection foldback overcurrent protection short circuit protection cord and connector 6 ft, 2 conductor, 18 awg, ault #3 connector. other connectors are also available. safety approvals agency listings curus2601, tuv/iec en60601-1 electrical topology switching-fixed frequency flyback leakage current less than 500 ua (ground) minimum 75% efficiency tbd minimum emi complies with emc directives ce ce compliant mtbf 100,000 calculated hours minimum environmental operating temperature 0o to 40o c with no derating storage temperature -30o to +85o c relative humidity 5% to 95% non-condensing altitude 0-10,000 feet cooling convectional - non vented case mechanical case and dimensions 3.74l x 2.13w x 1.26h (in) 95.0l x 54.0w x 32.0h (mm) case material 94v0 polycarbonate; black is standard color; other colors available - extra charges may apply weight 7 ounces, 198 grams


▲Up To Search▲   

 
Price & Availability of MW128XA070301

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X